   Emergency Running

Simulation: Failure in air supply

Test Set up (0 meter)

Abrasion and Granit after 5000 meters

Surface af Air Bearing after 300 meters

Surface af Air Bearing after 5000 meters

Test Set up:

  • Air bearing with nominal load with out air supply (simulation of failure in air supply)
  • Air bearing spin able around spherical fixation screw

Tribolic conditions:

  • Tribolic partner: Air bearing with emergency coating / granite
  • Tribolic condition: Dry running without air, without oil
  • Pressure on air bearing surface: 25 N/cm²
  • Relative speed: 0,25 m/s; constant
  • Size of bearing: Pad D = 50 mm
  • Force on bearing: 500 N (= nominal load at 5 bar)

Test results:

  • Load capacity of air bearing after test almost the same value as before the test
  • Granite with out demage
 
 